Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.
| KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA [ARCHIVED] |
|---|---|---|---|---|---|
| ACTION | N New | R Revision | C Change | D Deletion |
| Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
|---|---|---|---|---|---|---|
| May-2016 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 8 | Revised the following three subparts, 1.4.1, 1.4.3, 1.11.4, due to releasing Section 01 33 16.00 10 DESIGN DATA [DESIGN AFTER AWARDS] for use on USACE Design-Build projects only. |
| May-2016 | A | UFGS 01 33 16.00 10 Design Data (Design After Award) | May-2016 | N | New UFGS for use on USACE Design-Build projects only | |
| May-2016 | N | UFGS 01 35 26 Governmental Safety Requirements | Nov-2015 | C | 1 | Modified OSHA Form 300 and 300A requirements under Duties of the SSHO. |
| May-2016 | A | UFGS 01 42 00 Sources for Reference Publications | Nov-2014 | C | 1 | Added ONVIF and ICS |
| May-2016 | A | UFGS 01 78 24.00 10 Facility Data Requirements | May-2016 | N | New UFGS for maintenance and turnover of electronic Facility Data for use by Army O&M personnel and systems of record | |
| May-2016 | A | UFGS 01 91 00.15 Building Commissioning | May-2016 | N | Superseding UFGS 23 08 00.00 10 COMMISSIONING OF HVAC SYSTEMS; Total Building Commissioning requirements for new construction and major renovations. | |
| May-2016 | A | UFGS 03 23 00 Stressed Tendon Reinforcing | May-2016 | R | Complete review and update, including title change from STEEL STRESSING TENDONS AND ACCESSORIES FOR PRESTRESSED CONCRETE. | |
| May-2016 | A | UFGS 03 40 00.00 10 Plant-Precast Concrete Products for Below Grade Construction | Aug-2006 | D | Superseded by UFGS 03 42 13.00 10 with no title change. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | A | UFGS 03 42 13.00 10 Plant-Precast Concrete Products for Below Grade Construction | May-2016 | N | Superseding UFGS 03 40 00.00 10 with no title change. Complete review and update. | |
| May-2016 | N | UFGS 03 45 00 Precast Architectural Concrete | May-2016 | R | Complete review and revision of section. | |
| May-2016 | N | UFGS 03 45 33 Precast [Prestressed] Structural Concrete | May-2016 | R | Complete review and revision of section. | |
| May-2016 | A | UFGS 03 51 01 Precast Roof Decks | Jan-2008 | D | Superseded by UFGS 03 51 13 Cementitious Wood Fiber Decks. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | A | UFGS 03 51 13 Cementitious Wood Fiber Decks | May-2016 | N | Superseding UFGS 03 51 01 PRECAST ROOF DECKS. Complete review and update. | |
| May-2016 | N | UFGS 05 30 00 Steel Decks | May-2015 | C | 1 | Revised text in subpart 3.9.3 and relocated applicable Specifier Note below subpart 3.9.3 title. |
| May-2016 | N | UFGS 08 51 13 Aluminum Windows | May-2011 | C | 2 | CCR 3599: Removed ASTM D1972 reference from section and revised text in subpart 1.7 |
| May-2016 | N | UFGS 08 51 23 Steel Windows | Aug-2011 | C | 2 | CCR 4166: Removed subpart 2.2.6 and reference ASTM A167 |
| May-2016 | N | UFGS 08 52 00 Wood Windows | Aug-2011 | C | 2 | CCR 3600: Removed ASTM D1972 reference from section and revised text in subpart 1.4.1 |
| May-2016 | N | UFGS 14 21 00.00 20 Electric Traction Elevators | May-2012 | D | Superseded by completely revised UFGS sections 14 21 13 ELECTRIC TRACTION FREIGHT ELEVATORS and 14 21 23 ELECTRIC TRACTION PASSENGER ELEVATORS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | N | UFGS 14 21 13 Electric Traction Freight Elevators | May-2016 | R | Complete revision. Preparing Activity changed from USACE to NAVFAC. | |
| May-2016 | N | UFGS 14 21 23 Electric Traction Passenger Elevators | May-2016 | R | Complete revision. Preparing Activity changed from USACE to NAVFAC. | |
| May-2016 | A | UFGS 14 24 00 Hydraulic Elevators | Aug-2010 | D | Superseded by UFGS 14 24 13 HYDRAULIC FREIGHT ELEVATORS and UFGS 14 24 23 HYDRAULIC PASSENGER ELEVATORS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | N | UFGS 14 24 13 Hydraulic Freight Elevators | May-2016 | N | Superseding UFGS 14 24 00 HYDRAULIC ELEVATORS previously prepared by USACE. Complete review and update concerning hydraulic freight elevators. | |
| May-2016 | N | UFGS 14 24 23 Hydraulic Passenger Elevators | May-2016 | N | Superseding UFGS 14 24 00 HYDRAULIC ELEVATORS previously prepared by USACE. Complete review and update concerning hydraulic freight elevators. | |
| May-2016 | S | UFGS 21 22 00.00 40 Clean Agent Fire Extinguishing Systems | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | S | UFGS 21 22 00.00 40 Clean Agent Fire Extinguishing Systems | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | N | UFGS 22 00 00 Plumbing, General Purpose | Nov-2015 | C | 1 | Added Navy and Army/Air Force bracketed options to subpart 2.16 |
| May-2016 | S | UFGS 23 01 30.41 HVAC System Cleaning | Feb-2015 | C | 1 | The USACE DWG members have given their approval to delete the second paragraph regarding an Army Statement, found in the General Note. |
| May-2016 | A | UFGS 23 08 00.00 10 Commissioning of HVAC Systems | Jan-2008 | D | Superseded by UFGS 01 91 00.15 TOTAL BUILDING COMMISSIONING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | S | UFGS 23 31 13.00 40 Metal Ducts | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | S | UFGS 23 36 00.00 40 Air Terminal Units | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | N | UFGS 23 52 33.02 20 Steam Heating Plant Watertube (Field Erected) Coal/Oil or Coal | Nov-2008 | C | 2 | Administrative changes per CCR 580 |
| May-2016 | N | UFGS 23 52 46.00 20 Low Pressure Water Heating Boilers (Over 800,000 BTU/HR Output) | May-2015 | C | 2 | CCR 4532: revised use of "shall" and imperative language |
| May-2016 | S | UFGS 23 82 16.00 40 Air Coils | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | S | UFGS 23 82 16.00 40 Air Coils | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | A | UFGS 26 05 19.00 10 Insulated Wire and Cable | Nov-2008 | D | Superseded by UFGS 26 05 19.10 10 with no title change. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | A | UFGS 26 05 19.10 10 Insulated Wire and Cable | May-2016 | N | Superseding UFGS 26 05 19.00 10 INSULATED WIRE AND CABLE; section has been updated | |
| May-2016 | N | UFGS 26 51 00 Interior Lighting | May-2016 | R | Complete revision that includes a new and different product, LED light sources and LED light fixtures. | |
| May-2016 | S | UFGS 26 56 19.00 40 Roadway Lighting | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | S | UFGS 26 56 19.00 40 Roadway Lighting | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | S | UFGS 26 56 36.00 40 Flood Lighting | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | S | UFGS 26 56 36.00 40 Flood Lighting | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | A | UFGS 28 08 10 Electronic Security System Acceptance Testing | May-2016 | N | New UFGS for acceptance testing of electronic security systems | |
| May-2016 | A | UFGS 28 10 05 Electronic Security Systems (ESS) | May-2016 | N | UFGS for Electronic Security Systems (ESS) consisting of commercial off-the-shelf equipment. Superseding UFGS 28 16 00.00 20 BASIC INTRUSION DETECTION SYSTEMS (IDS), UFGS 28 16 01.00 10 SMALL INTRUSION DETECTION SYSTEM, UFGS 28 20 00.00 20 ELECTRONIC SECURITY SYSTEMS (ESS), COMMERCIAL, UFGS 28 20 01.00 10 ELECTRONIC SECURITY SYSTEM, and UFGS 28 23 23.00 10 CLOSED CIRCUIT TELEVISION SYSTEMS. | |
| May-2016 | N | UFGS 28 16 00.00 20 Basic Intrusion Detection System (IDS) | Apr-2006 | D | Superseded by UFGS 28 10 05 Electronic Security Systems (ESS). Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | A | UFGS 28 16 01.00 10 Small Intrusion Detection System | Nov-2008 | D | Superseded by UFGS 28 10 05 Electronic Security Systems (ESS). Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | N | UFGS 28 20 00.00 20 Electronic Security Systems (ESS) Commercial | Apr-2006 | D | Superseded by UFGS 28 10 05 Electronic Security Systems (ESS). Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | A | UFGS 28 20 01.00 10 Electronic Security System | Oct-2007 | D | Superseded by UFGS 28 10 05 Electronic Security Systems (ESS). Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | A | UFGS 28 23 23.00 10 Closed Circuit Television Systems | Feb-2011 | D | Superseded by UFGS 28 10 05 Electronic Security Systems (ESS). Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | A | UFGS 31 31 16.13 Chemical Termite Control | Nov-2014 | C | 1 | Update to referenced website URLs |
| May-2016 | N | UFGS 32 92 19 Seeding | Oct-2006 | C | 1 | CCR 4742: Revised subpart 3.4.4 |
| May-2016 | N | UFGS 33 01 30.72 Relining Sewers | May-2016 | N | Superseding 33 01 99 Slip Lining of Existing Piping (Preparing Activity NASA). | |
| May-2016 | S | UFGS 33 01 99 Slip Lining of Existing Piping | May-2009 | D | Superseded by UFGS Section 33 01 30.72 Relining Sewers; Preparing Activity changed from NASA to NAVFAC. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | S | UFGS 33 01 99 Slip Lining of Existing Piping | May-2009 | D | Superseded by UFGS Section 33 01 30.72 Relining Sewers; Preparing Activity changed from NASA to NAVFAC. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| May-2016 | N | UFGS 33 11 00 Water Utility Distribution Piping | May-2016 | R | Title changed from WATER DISTRIBUTION; revised throughout, superseding the previous section. | |
| May-2016 | F | UFGS 33 12 33.00 30 Water Meters | Nov-2011 | C | 1 | Section retitled from WATER UTILITY METERING |
| May-2016 | S | UFGS 40 17 30.00 40 Welding General Piping | May-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| May-2016 | S | UFGS 40 17 30.00 40 Welding General Piping | May-2016 | R | Tri-Annual Database Maintenance and the revisions are minor - modified Subpart 1.3.1, 1.5, 3.1.1.2, 3.2.1, 3.3, 3.3.1 | |
| May-2016 | N | UFGS 46 07 53.13 Packaged Wastewater Treatment Equipment, Aeration | Feb-2011 | C | 3 | CCR 4187: Removed ASTM A167 reference from section. CCR 4581: Revised subpart 2.13.8 by replacing ASTM A176 with ASTM A240/A240M. |
| Feb-2016 | N | UFGS 01 14 00 Work Restrictions | Nov-2011 | C | 3 | Added requirement for utility cutover and connection to existing sanitary sewer line. |
| Feb-2016 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 7 | Incorporated outstanding CCR's. |
| Feb-2016 | A | UFGS 01 50 00 Temporary Construction Facilities and Controls | Aug-2009 | C | 3 | Added provision for dumpsters tailored to NAVFAC SE |
| Feb-2016 | A | UFGS 04 21 26 Glazed Structural Clay Tile and Prefaced Concrete Masonry | Nov-2009 | D | Requirements transferred to UFGS 04 20 00 UNIT MASONRY (11/15 Release) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 04 25 13 Metal-Supported Unit Masonry Panels | Oct-2007 | D | Requirements transferred to UFGS 04 20 00 UNIT MASONRY (11/15 Release) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | N | UFGS 05 51 33 Metal Ladders | Feb-2016 | R | Revised to incorporate the addition of ladder safety device requirement and editorial changes. | |
| Feb-2016 | N | UFGS 06 20 00 Finish Carpentry | Feb-2016 | R | Complete revision; revised throughout to incorporate ccrs 2803, 1484,and 2424; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 12 00 Built-Up Bituminous Waterproofing | Feb-2016 | R | Complete revision; revised throughout to incorporate CCR 3686 ; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 13 53 Elastomeric Sheet Waterproofing | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 3687, 3463; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 17 00 Bentonite Waterproofing | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 2803, 1484,and 2424; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 21 13 Board and Block Insulation | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 2820, 3234; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 22 00 Roof and Deck Insulation | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 4254, 2807; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 92 00 Joint Sealants | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 2376 and 3692 update format and editorial changes | |
| Feb-2016 | N | UFGS 08 71 00 Door Hardware | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 4818, 1613, 3999, 2450, 2451, 2762, 1612, 3384, and 3386; update format and editorial changes | |
| Feb-2016 | A | UFGS 09 30 10 Ceramic, Quarry, and Glass Tiling | Nov-2013 | C | 1 | Corrected Section title, was CEMENT TILING, QUARRY TILING, AND PAVER TILING; corrected tailoring |
| Feb-2016 | N | UFGS 09 67 23.16 Fuel Resistive Resinous Flooring, 5-Coat System | Aug-2010 | C | 1 | Change to clarify that vendor products named are pretested for specification compliance. These and additional vendors and products may be submitted for review of compliance with test results in accordance with this specification; editorial updates. |
| Feb-2016 | N | UFGS 09 97 13.27 High Performance Coating for Steel Structures | Feb-2016 | R | This spec is a complete revision to reflect a new and different product. The spec was modified to move from Epoxy/ Polyurethane MIL Spec products to low VOC polysulfide modified novolac epoxy. Updates to QA/QC procedures and reporting requirements were also added. | |
| Feb-2016 | N | UFGS 11 41 11 Refrigerated and Frozen Food Storage Equipment | Feb-2016 | R | Complete revision; updated format and editorial changes. | |
| Feb-2016 | N | UFGS 11 42 00 Food Preparation Equipment | Feb-2016 | R | Complete revision; updated format and editorial changes. | |
| Feb-2016 | N | UFGS 13 21 26 Cold-Storage Rooms (Prefabricated Panel Type) | Feb-2016 | R | Complete revision; updated format and editorial changes | |
| Feb-2016 | A | UFGS 22 10 00.00 10 Vertical Pumps, Axial-Flow and Mixed-Flow Impeller-Type | Jul-2007 | D | Superseded by UFGS 35 45 01 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 22 11 23.00 10 Submersible Pump, Axial-Flow and Mixed-Flow Type | Jul-2007 | D | Superseded by UFGS 35 45 02.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 23 40 00.00 10 Chemical, Biological, and Radiological (CBR) Air Filtration System | Oct-2007 | D | Superseded by UFGS 23 44 00.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | S | UFGS 23 41 13.00 40 Panel Filters | Feb-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2016 | A | UFGS 23 44 00.00 10 Chemical, Biological, and Radiological (CBR) Air Filtration System | Feb-2016 | N | Superseding UFGS 23 40 00.00 10 of the same title. Complete review and update to include renaming for compliance with current MasterFormat. | |
| Feb-2016 | A | UFGS 23 50 52.00 10 Central High Temperature Water (HTW) Generating Plant and Auxiliaries | Feb-2016 | N | Superseding UFGS 33 60 00.00 10 of the same title. Complete review and update to include renaming for compliance with current MasterFormat. | |
| Feb-2016 | N | UFGS 23 82 00.00 20 Terminal Heating Units | Feb-2016 | R | Revised throughout to incorporate CCRs 1734, 4179, 4406 and 4716. Title changed from TERMINAL HEATING AND COOLING UNITS. Modifications included, references, infrared heaters and electrical work. | |
| Feb-2016 | S | UFGS 27 21 00.00 40 Intercommunication System | Feb-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2016 | S | UFGS 27 21 00.00 40 Intercommunication System | Feb-2016 | R | Tri-Annual Database Maintenance which includes, updating CSI Section Format per latest UFC 1-300-02; modified text in General Not and Part 1, deleted Subpart 1.2, 1.3, 1.3.1, 1.3.2, 1.3.3,added Subpart 2.1 - 2.1.1.3, modified 2.2.4 - 2.2.4.2; Submittal Article compliance, Imperative language | |
| Feb-2016 | N | UFGS 31 31 16.19 Termite Control Barriers | Feb-2016 | R | Section and title revised to combine UFGS 31 31 16.19 (was) MESH TERMITE CONTROL BARRIER SYSTEM and UFGS 31 31 16.20 BASALTIC TERMITE BARRIER and UFGS 31 31 16.21 MESH TERMITE BARRIER (deleted February 2015) to reduce specifications containing similar content and updated to reflect current criteria format. | |
| Feb-2016 | N | UFGS 31 31 16.20 Basaltic Termite Barrier | Apr-2006 | D | Superseded by UFGS 31 31 16.19 Termite Control Barriers Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | N | UFGS 32 01 13.63 Gilsonite Modified Asphalt Emulsion Seal Coats | Feb-2016 | N | New UFGS Section | |
| Feb-2016 | S | UFGS 33 05 23.13 Utility Horizontal Directional Drilling | Nov-2013 | C | 1 | Performed updating of Section Format, imperative language, formatting review, and Submittal Article clean up |
| Feb-2016 | A | UFGS 33 30 00 Sanitary Sewerage | Apr-2008 | C | 4 | Additional requirements to prevent cross connection of sanitary with storm sewer |
| Feb-2016 | A | UFGS 33 45 00.00 10 Speed Reducers for Storm Water Pumps | Apr-2008 | D | Superseded by UFGS 35 45 03.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 51 15 Natural-Gas / Liquid Petroleum Gas Distribution Pipelines | Feb-2016 | R | Complete review and update. | |
| Feb-2016 | A | UFGS 33 60 00.00 10 Central High Temperature Water (HTW) Generating Plant and Auxiliaries | Apr-2008 | D | Superseded by UFGS 23 50 52.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 60 01 Valves, Piping, and Equipment in Valve Manholes | Apr-2008 | D | Superseded by UFGS 33 61 13.19 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 61 00 Prefabricated Underground Heating / Cooling Distribution System | Apr-2008 | D | Superseded by UFGS 33 61 13.13 PREFABRICATED UNDERGROUND HYDRONIC ENERGY DISTRIBUTION Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 61 13.13 Prefabricated Underground Hydronic Energy Distribution | Feb-2016 | N | Superseding UFGS 33 61 00 PREFABRICATED UNDERGROUND HEATING/COOLING DISTRIBUTION SYSTEM. Complete review and update to include renaming and re-titling for compliance with current MasterFormat. | |
| Feb-2016 | A | UFGS 33 61 13.19 Valves, Piping, and Equipment in Valve Manholes | Feb-2016 | N | Superseding UFGS 33 60 01 of the same title. Complete review and update to include renaming for compliance with current MasterFormat. | |
| Feb-2016 | A | UFGS 33 61 15 Heat Distribution Systems in Concrete Trenches | Jul-2006 | D | Superseded by UFGS 33 63 13.19 CONCRETE TRENCH HYDRONIC AND STEAM ENERGY DISTRIBUTION Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |