Status
Active
Publish Date
Pages
47
Legacy Title Key
UFGS 07 52 00 Modified Bituminous Membrane Roofing

Comments

Release
PA
Navy
Action
Change

Added notes throughout the specification and notes to the specifier prohibiting torch application of the roofing system when the roof deck, the materials used in the installation of the roofing system, or the existing roof deck or materials are combustible as defined by NFPA 101. Added required submittal to Submittals Article (1.3) of torch applicators CERTA card. Added requirement in paragraph "Preroofing Conference" (1.4.8-g). for torch operator to attend the preroofing conference. Added requirement in paragraph "Fire Watch" (1.7.2) for the use of thermal heat imager during the firewatch.

Release
PA
Navy
Action
Change

Sustainability updates required to coordinate with the Federal Codes and DoD policies and procedures.

Release
PA
Navy
Action
Change

Changed Material Safety Data Sheets (MSDS) to Safety Data Sheets (SDS).

Release
PA
Navy
Action
Change

Fixed typo under "Substrate Preparation. Changed "Don not" to "Do not"

Release
PA
Navy
Action
Change

Modified note before Part 1, subparts 1.2, 1.7.1, 1.9.1, 1.12, 2.1 efg

Release
PA
Navy
Action
Revision

Major revision

Release
PA
Navy
Action
Revision

Reference changed from FM AS 4470 to FM 4470

Release
PA
Navy
Action
Revision

Incorporated NASA requirements

Release
PA
Navy
Action
Revision

Added English and metric tags throughout.

Spec. Division
07 - Thermal and Moisture Protection