About the UFC Program

The Unified Facilities Criteria (UFC) Program provides planning, design, construction, sustainment, restoration, and modernization criteria for Department of Defense (DoD) facilities. These criteria apply to the Military Departments, Defense Agencies, and DoD Field Activities in accordance with DoD Directive 4270.5 (Military Construction) and the USD(AT&L) Memorandum dated 29 May 2002. UFC program content is distributed exclusively in electronic format and are effective upon issuance.

The UFC Program is jointly administered by the United States Army Corps of Engineers (HQUSACE), Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (AFCEC). Program procedures and points of contact are outlined in the current edition of MIL-STD-3007.

Program Structure: UFC, UFS, and UFM

The UFC Program delivers consistent technical content through three types of unified components:

  • Unified Facilities Criteria (UFC): Technical requirements, laws, and policies applicable across all DoD Components. This criterion is considered mandatory unless a waiver is granted. UFC may contain Commentary as indicated by [C]. This Commentary is helpful information to expand upon the UFC criteria.
  • Unified Facilities Supplement (UFS): Supplemental information that supports UFCs with guidance, best practices, checklists, procedures, or component-specific needs. This is not mandatory criteria and is provided For Information Only (FIO).
  • Unified Facilities Operations & Maintenance Manual (UFM): Operations and maintenance manuals that guide implementation and may expand on requirements elsewhere.

Together, this unified criteria program ensures consistent standards for safety, sustainability, durability, and functionality. UFCs incorporate building codes, DoD requirements, and applicable statutory provisions. UFC content that is fully unified and applicable across all DoD Components have no alphabetical suffix in the title.

Non-Unified Content: FC, FS, FM

When content is developed for a specific agency or limited audience, it is reclassified as:

  • Facilities Criteria (FC): Non-unified counterpart to UFC, tailored to specific facility or Component needs.
  • Facilities Supplements (FS): Non-unified counterpart to UFS, providing Component-specific technical or contextual content. This is not criteria and is provided For Information Only (FIO).
  • Facilities Manuals (FM): Non-unified counterpart to UFM, delivering O&M content for Component-specific requirements.

Non-unified documents include a letter at the end of their number to show the sponsoring Component:

  • A — U.S. Army Corps of Engineers (USACE)
  • N — Naval Facilities Engineering Systems Command (NAVFAC)
  • F — Air Force Civil Engineer Center (AFCEC)

If applicable to multiple agencies, multiple letters are used (e.g., AF for Army and Air Force).

Glossary and References

Glossary terms will no longer be included in UFCs. Instead, you may find this information at the following:

Questions and Change Requests

Suggestions, comments, and recommended changes to UFC Program documents are encouraged and should be submitted via a Criteria Change Request (CCR). To submit a CCR, click the CCR link provided next to each document. CCRs should not be used for project-specific issues, such as solicitation or contract interpretation. These matters should be directed to the appropriate Contracting Officer.

To learn more about how changes are classified, refer to the UFC—UFGS Revision-Change Policy.

 A paperclip icon next to a UFC title indicates an attachment is available. Click the title to view the related materials.

 

? Active: Document is current, regularly maintained by the responsible DWG through formal revisions and changes, and must be used in accordance with its applicability paragraphs.

Inactive: Document is not regularly maintained due to limited use. May be used for new projects per applicability paragraphs, but users must verify content relevancy and accept responsibility for using potentially outdated information.

Archived: Document is outdated or superseded and not maintained. Prohibited for use in new projects. Available only for historical reference or for existing projects that previously cited the document before archival.


TITLE Date Change Date View CCR
UFC Complete  
UFC 1-200-01 DoD Building Code, with Change 4   View/Download   CCR  
UFC 1-200-02 High Performance and Sustainable Building Requirements, with Change 3   View/Download   CCR  
UFC 1-201-01 Non-Permanent DoD Facilities in Support of Military Operations, with Change 4   View/Download   CCR  
UFC 1-201-02 Assessment of Existing Facilities for Use in Military Operations   View/Download   CCR  
UFC 1-300-01 Criteria Format Standard, with Change 1  , View/Download   CCR  
UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard, with Change 3    View/Download   CCR  
UFC 1-300-08 Criteria for Transfer and Acceptance of DoD Real Property   View/Download   CCR  
FC 1-300-09N Navy and Marine Corps Design Procedures, with Change 1   View/Download   CCR  
FC 2-000-05N Facility Planning Criteria for Navy and Marine Corps Shore Installations   View Webpage  
UFC 2-100-01 Installation Master Planning, with Change 2   View/Download   CCR  
UFC 3-101-01 Architecture, with Change 4   View/Download   CCR  
UFC 3-110-03 Roofing, with Change 5   View/Download   CCR  
UFC 3-120-01 Design: Sign Standards, with Change 4   View/Download   CCR  
UFC 3-120-10 Interior Design, with Change 3   View/Download   CCR  
UFC 3-130-01 Arctic and Subarctic Engineering   View/Download   CCR  
UFC 3-130-02 Arctic and Subarctic Site Assessment and Selection   View/Download   CCR  
UFC 3-130-03 Arctic and Subarctic Foundations for Freezing and Thawing Conditions   View/Download   CCR  
UFC 3-130-04 Arctic and Subarctic Buildings   View/Download   CCR  
UFC 3-130-05 Arctic and Subarctic Utilities   View/Download   CCR  
UFC 3-190-06 Protective Coatings and Paints   View/Download   CCR  
UFC 3-201-01 Civil Engineering   View/Download   CCR  
UFC 3-201-02 Landscape Architecture, with Change 1   View/Download   CCR  
UFC 3-210-10 Low Impact Development   View/Download   CCR  
UFC 3-220-01 Geotechnical Engineering, with Change 3   View/Download   CCR  
UFC 3-220-10 Soil Mechanics (DM 7.1), with Change 1   View/Download   CCR  
UFC 3-220-20 Foundations and Earth Structures (DM 7.2)   View/Download   CCR  
UFC 3-230-01 Water Storage and Distribution with Change 3   View/Download   CCR  
UFC 3-230-02 O&M: Water Supply Systems, with Change 2   View/Download   CCR  
UFC 3-230-03 Water Treatment, with Change 2   View/Download   CCR  
UFC 3-230-13 Industrial Water Treatment Operation and Maintenance   View/Download   CCR  
UFC 3-240-01 Wastewater Collection and Treatment, with Change 4   View/Download   CCR  
UFC 3-240-03 Operation and Maintenance (O&M): Wastewater Treatment, with Change 1   View/Download   CCR  
UFC 3-240-11 Landfills in Support of Military Operations   View/Download   CCR  
UFC 3-250-01 Pavement Design for Roads and Parking Areas  , View/Download   CCR  
UFC 3-250-03 Standard Practice Manual for Flexible Pavements   View/Download   CCR  
UFC 3-250-04 Standard Practice for Concrete Pavement Construction   View/Download   CCR  
UFC 3-250-07 Standard Practice for Pavement Recycling   View/Download   CCR  
UFC 3-250-11 Soil Stabilization and Modification for Pavements   View/Download   CCR  
UFC 3-260-01 Airfield and Heliport Planning and Design, with Change 1   View/Download   CCR  
UFC 3-260-02 Pavement Design for Airfields   View/Download   CCR  
UFC 3-260-03 O&M Manual: Standard Practice for Airfield Pavement Evaluation   View/Download   CCR  
UFC 3-260-04 Airfield and Heliport Marking   View/Download   CCR  
FC 3-260-06F Air Force Design, Construction, Maintenance, and Evaluation of Snow and Ice Airfields in Antarctica   View/Download   CCR  
UFC 3-260-16 O&M Manual: Standard Practice for Airfield Pavement Condition Surveys   View/Download   CCR  
UFC 3-260-17 Dust Control for Roads, Airfields and Adjacent Areas, with Change 1   View/Download   CCR  
FC 3-260-18F Air Force Aircraft Arresting Systems Installation, Operation, and Maintenance, with Change 1   View/Download   CCR  
UFC 3-270-01 O&M Manual: Asphalt and Concrete Pavement Maintenance and Repair, with Change 1   View/Download   CCR  
UFC 3-270-08 Pavement Management   View/Download   CCR  
UFC 3-301-01 Structural Engineering, with Change 4  , View/Download   CCR  
UFC 3-301-02 Design of Risk Category V Structures, National Strategic Military Assets, with Change 1  , View/Download   CCR  
UFC 3-310-08 Non-Expeditionary Bridge Inspection, Maintenance and Repair   View/Download   CCR  
UFC 3-340-01 Design and Analysis of Hardened Structures to Conventional Weapons Effects (FOUO)   View/Download   CCR  
UFC 3-340-02 Structures to Resist the Effects of Accidental Explosions, with Change 2   View/Download   CCR  
UFC 3-401-01 Mechanical Engineering   View/Download   CCR  
FC 3-401-02N Navy and Marine Corps Existing Building Commissioning  , View/Download   CCR  
UFC 3-410-01 Heating, Ventilating, and Air Conditioning Systems  , View/Download   CCR  
UFC 3-410-02 Direct Digital Control for HVAC and Other Building Control Systems, with Change 2  , View/Download   CCR  
UFC 3-410-04 Industrial Ventilation   View/Download   CCR  
UFC 3-420-01 Plumbing Systems   View/Download   CCR  
UFC 3-420-02 Compressed Air   View/Download   CCR  
UFC 3-430-05 Natural Gas and Liquefied Petroleum Gas (LPG) Distribution Pipelines   View/Download   CCR  
UFC 3-430-09 Exterior Mechanical Utility Distribution   View/Download   CCR  
UFC 3-430-11 Boiler Plant Instrumentation and Control Systems   View/Download   CCR  
UFC 3-440-01 Facility-Scale Renewable Energy Systems   View/Download   CCR  
UFC 3-450-01 Noise and Vibration Control   View/Download   CCR  
UFC 3-460-01 Design: Petroleum Fuel Facilities, with Change 3   View/Download   CCR  
UFC 3-460-03 Petroleum Fuel Systems Maintenance, with Change 2   View/Download   CCR  
UFC 3-470-01 Utility Monitoring and Control System (UMCS) Front End and Integration   View/Download   CCR  
UFC 3-490-06 Elevators, with Change 1   View/Download   CCR  
UFC 3-501-01 Electrical Engineering   View/Download   CCR  
UFC 3-510-01 Foreign Voltages and Frequencies Guide, with Change 2   View/Download   CCR  
UFC 3-520-01 Interior Electrical Systems   View/Download   CCR  
UFC 3-520-02 Facility Energy System Resilience and Reliability, with Change 1   View/Download   CCR  
UFC 3-520-05 Stationary and Mission Batteries, with Change 2   View/Download   CCR  
UFC 3-530-01 Interior and Exterior Lighting Systems, with Change 1   View/Download   CCR  
UFC 3-535-01 Visual Air Navigation Facilities, with Change 4   View/Download   CCR  
UFC 3-535-02 Design Drawings for Visual Air Navigation Facilities  , View/Download   CCR  
UFC 3-540-01 Engine-Driven Generator Systems for Prime and Standby Power Applications, with Change 3   View/Download   CCR  
UFC 3-540-07 Operation and Maintenance (O&M): Generators, with Change 1   View/Download   CCR  
UFC 3-540-08 Utility-Scale Renewable Energy Systems   View/Download   CCR  
UFC 3-550-01 Exterior Electrical Power Distribution, with Change 3   View/Download   CCR  
UFC 3-550-04 Resilient Installation Microgrid Design   View/Download   CCR  
UFC 3-550-07 Operation and Maintenance (O&M): Exterior Power Distribution Systems   View/Download   CCR  
UFC 3-555-01 Aircraft Point-of-Use Power Systems   View/Download   CCR  
UFC 3-560-01 Operation and Maintenance: Electrical Safety, with Change 3   View/Download   CCR  
UFC 3-570-01 Cathodic Protection, with Change 1   View/Download   CCR  
UFC 3-570-06 Operation and Maintenance: Cathodic Protection Systems   View/Download   CCR  
UFC 3-575-01 Lightning and Static Electricity Protection Systems, with Change 1   View/Download   CCR  
UFC 3-580-01 Information and Communications Technology Infrastructure Planning and Design  , View/Download   CCR  
UFC 3-600-01 Fire Protection Engineering for Facilities, with Change 6   View/Download   CCR  
UFC 3-601-02 Fire Protection Systems Inspection, Testing, and Maintenance, with Change 1   View/Download   CCR  
UFC 3-701-01 DoD Facilities Pricing Guide, with Change 7  , View/Download   CCR  
UFC 3-730-01 Programming Cost Estimates for Military Construction  , View/Download   CCR  
UFC 3-740-05 Construction Cost Estimating  , View/Download   CCR  
UFC 3-810-01 Environmental Engineering for Facility Construction   View/Download   CCR  
UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings, with Change 3   View/Download   CCR  
UFC 4-010-05 SCIF/SAPF Planning, Design, and Construction   View/Download   CCR  
UFC 4-010-06 Cybersecurity of Facility-Related Control Systems (FRCS)  , View/Download   CCR  
UFC 4-020-01 DoD Security Engineering Facilities Planning Manual   View/Download   CCR  
UFC 4-021-01 Design and O&M: Mass Notification Systems, with Change 1   View/Download   CCR  
UFC 4-021-02 Electronic Security Systems  , View/Download   CCR  
UFC 4-022-01 Security Engineering: Entry Control Facilities / Access Control Points   View/Download   CCR  
UFC 4-022-02 Selection and Application of Vehicle Barriers, with Change 1   View/Download   CCR  
UFC 4-022-03 Security Fences and Gates   View/Download   CCR  
UFC 4-023-03 Design of Buildings to Resist Progressive Collapse, with Change 4   View/Download   CCR  
UFC 4-023-07 Design to Resist Direct Fire Weapons Effects, with Change 1   View/Download   CCR  
UFC 4-023-10 Safe Havens   View/Download   CCR  
UFC 4-025-01 Security Engineering: Waterfront Security   View/Download   CCR  
UFC 4-026-01 Design to Resist Forced Entry   View/Download   CCR  
UFC 4-027-01 Design of Deployed Operational Bases to Mitigate Terrorist Attacks (CUI)   View/Download  
UFC 4-133-01 Air Traffic Control and Air Operations Facilities, with Change 2   View/Download   CCR  
UFC 4-141-03 Command, Control, Computers, Communications, Cyber-Defense, Intelligence, Surveillance, And Reconnaissance (C5ISR) Facilities   View/Download   CCR  
UFC 4-141-10 Airfield Operations Support Facilities   View/Download   CCR  
UFC 4-150-02 Dockside Utilities for Ship Service   View/Download   CCR  
UFC 4-150-06 Military Harbors and Coastal Facilities, with Change 1   View/Download   CCR  
UFC 4-150-07 Maintenance and Operation: Maintenance of Waterfront Facilities, with Change 1   View/Download   CCR  
UFC 4-150-08 Mooring Hardware Inspection   View/Download   CCR  
UFC 4-150-09 Permanent Anchored Moorings Operations and Maintenance   View/Download   CCR  
UFC 4-151-10 General Criteria for Waterfront Construction, with Change 1   View/Download   CCR  
UFC 4-152-01 Piers and Wharves, with Change 1   View/Download   CCR  
UFC 4-152-07 Design: Small Craft Berthing Facilities, with Change 1   View/Download   CCR  
UFC 4-159-03 Moorings   View/Download   CCR  
FC 4-171-06N Navy Operational Support Center   View/Download   CCR  
UFC 4-179-02 Small Arms Ranges, with Change 1   View/Download   CCR  
FC 4-179-03F Air Force Indoor Small Arms Firing Range, with Change 2   View/Download   CCR  
UFC 4-211-01 Aircraft Maintenance Hangars, with Change 3  , View/Download   CCR  
UFC 4-211-02 Aircraft Corrosion Control and Paint Facilities   View/Download   CCR  
FC 4-211-03F Air Force Fighter Engine Maintenance Facility   View/Download   CCR  
UFC 4-213-10 Graving Dry Docks   View/Download   CCR  
UFC 4-214-03 Central Vehicle Wash Facilities   View/Download   CCR  
UFC 4-215-01 Armories and Arms Rooms   View/Download   CCR  
FC 4-218-01F Air Force Criteria for Precision Measurement Equipment Laboratory Design and Construction, with Change 2   View/Download   CCR  
UFC 4-310-03 DoD Fuels Laboratory Standards   View/Download   CCR  
UFC 4-420-01 Ammunition and Explosives Storage Magazines   View/Download   CCR  
FC 4-420-07F Nuclear Weapons-Capable Maintenance and Storage Facilities   View/Download   CCR  
UFC 4-440-01 Warehouses and Storage Facilities, with Change 1   View/Download   CCR  
UFC 4-510-01 Design: Military Medical Facilities, with Change 4   View/Download   CCR  
UFC 4-610-01 Administrative Facilities, with Change 1   View/Download   CCR  
FC 4-610-04F Air Force Legal Facilities   View/Download   CCR  
UFC 4-711-01 Family Housing, with Change 3   View/Download   CCR  
UFC 4-720-01 Lodging Facilities   View/Download   CCR  
FC 4-721-10N Navy and Marine Corps Unaccompanied Housing, with Change 1   View/Download   CCR  
UFC 4-722-01 Design: Dining Facilities   View/Download   CCR  
UFC 4-730-01 Military Family Service Centers   View/Download   CCR  
UFC 4-730-10 Fire Stations, with Change 1  , View/Download   CCR  
UFC 4-740-02 Fitness Centers, with Change 1   View/Download   CCR  
UFC 4-740-06 Youth Centers, with Change 1   View/Download   CCR  
FC 4-740-14N Navy and Marine Corps Child Development Centers   View/Download   CCR  
UFC 4-740-15 Continuous Child Care Facilities   View/Download   CCR